fix: run the W5500 SPI bus at 10 MHz

At 20 MHz the controller intermittently dropped every Ethernet frame
over about 900 bytes, while small packets got through. The web UI then
hung after the first chunk of a response. At 10 MHz, full-size pings
and repeated fetches of every UI file all succeed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
jimmyandClaude Opus 5.5 committed 2026-11-03 00:50:46 +13:00
1 parent 32c0ecfa76
commit 9d628aa3c8
1 file changed
+1 -1
+1 -1
View File
@@ -8,7 +8,7 @@ menu "W5500 config"
config W5500_SPI_CLOCK_MHZ
int "SPI clock speed (MHz)"
range 5 80
default 20
default 10
config W5500_SCLK_GPIO
int "SCLK GPIO (XIAO D8)"