Add support for displaying and changing the various STK500 operational
parameters. git-svn-id: svn://svn.savannah.nongnu.org/avrdude/trunk/avrdude@336 81a1dc3b-b13d-400b-aceb-764788c761c2
This commit is contained in:
@@ -555,6 +555,33 @@ Leave terminal mode and thus AVRDUDE.
|
||||
|
||||
@end table
|
||||
|
||||
@noindent
|
||||
In addition, the following commands are supported on the STK500
|
||||
programmer:
|
||||
|
||||
@table @code
|
||||
|
||||
@item vtarg @var{voltage}
|
||||
Set the target's supply voltage to @var{voltage} Volts.
|
||||
|
||||
@item varef @var{voltage}
|
||||
Set the adjustable voltage source to @var{voltage} Volts.
|
||||
This voltage is normally used to drive the target's
|
||||
@emph{Aref} input on the STK500.
|
||||
|
||||
@item fosc @var{freq}[@var{M}|@var{k}]
|
||||
Set the master oscillator to @var{freq} Hz.
|
||||
An optional trailing letter @var{M}
|
||||
multiplies by 1E6, a trailing letter @var{k} by 1E3.
|
||||
|
||||
@item fosc off
|
||||
Turn the master oscillator off.
|
||||
|
||||
@item parms
|
||||
Display the current voltage and master oscillator parameters.
|
||||
|
||||
@end table
|
||||
|
||||